How do I adjust the step out of my cut that occurs while backscoring?

Parallel Guide (Healing/Tracking) Adjustment for Striebigs Models – Econom, Standard, Automat, Optisaw I, Optisaw I Plus, Optisaw II & Standard TRK

1. Test for healing by making a climb-scoring (or main-blade scoring) pass and returning back through with a finish cut. Retract the riving knife (splitting wedge) before cutting. The test is the same, but independent, for both vertical and horizontal directions. Examine both sides of the cut for a scoring step, or shoulder, on one side of the cut or the other. The side of the step will correlate to the side that the back of the saw blade is leaning. In other words, if the scoring step is on the left side of the cut (on a vertical cut), then the saw blade is oriented as if at 11 :00 and 5 :00 and needs to be adjusted slightly clockwise.

2. For vertical mode adjustment, (position #65) loosen the two nuts on the nylon screws with the 13mm wrench, while holding the screws in position with a screwdriver.

3. Back off the rear screw (furthest from the frame) at least half a tum to take it out of the equation. The actual adjustment will be made with the lead screw.

4. In the case example described above, the lead screw would be turned clockwise, or inward, in order to adjust the saw head clockwise. The adjustments are generally small, so start with quarter tum adjustments. Lightly tighten the nut to the lead screw only and make another test cut.

5. Verify that you are moving the saw head in the right direction (making the step less visible) and proceed with further adjustment and testing with the lead screw only, until there is no noticeable step on either side of the test cut.

6. Once you have the healing corrected with the lead screw, move the saw head in to the point where the rear screw can contact the flat portion of the guide bar and adjust it in until it just barely touches the guide bar and lightly tighten the nut.

7. Adjust the take-up spring block on the other side of the guide bar with a 5mm Allen wrench so that there is no play, or slop, in the saw head, but also so that there is no significant drag as you plunge the saw head. Make sure the spring block is parallel to the stationary guide bar that it is contacting.

8. The adjustment for the horizontal cut (position #65) is done exactly the same way except that the parallel guide mechanism is a mirror image (the screws are on the left side of the guide bar. Be certain to return the riving knife when finished.

Find More Troubleshooting Suggestions

Striebigs are extremely reliable when maintained properly. If you experience an issue and would like to troubleshoot independently, below are a few procedures to address them.

Please note: Some procedures refer to parts that may differ slightly from your Striebig model. If you have questions, please contact Colonial Saw.

Filter by Topic

Why am I cutting into my grid laths?

Replacing Grid Deflecting Device Assembly (C) Models – Econom, Standard, Optisaw 1, Optisaw I Plus, Optisaw II & Standard TRK machines With saw head horizontal: 1. Unhook thinner spring #56 from carriage safety brake bolt #21. 2. Back off Allen head set screw just below bolt #20 holding top of hollow rod with 3mm Allen…

See Full Answer

How do I adjust the scoring blade?

OperationGeometry of a scoring cut The scoring and separating cut made on a plastic laminated panel is as follows if a two-part scoring saw is used for the purpose of scoring. Scoring saw blade A variety of scoring saw blades are available from the trade. The choice of the right scoring saw blade is not…

See Full Answer

Where does the rod with 2 brass ends go on my saw?

Replacing Grid Deflecting Device Assembly (C) Econom, Standard, Optisaw 1, Optisaw I Plus, Optisaw II & Standard TRK machines With saw head horizontal: 1. Unhook thinner spring #56 from carriage safety brake bolt #21. 2. Back off Allen head set screw just below bolt #20 holding top of hollow rod with 3mm Allen wrench. With…

See Full Answer

How do I replace the deflector mechanism?

Replacing Grid Deflecting Device Assembly (C) Econom, Standard, Optisaw 1, Optisaw I Plus, Optisaw II & Standard TRK machines With saw head horizontal: 1. Unhook thinner spring #56 from carriage safety brake bolt #21. 2. Back off Allen head set screw just below bolt #20 holding top of hollow rod with 3mm Allen wrench. With…

See Full Answer

Why do my measured dimensions move when I plunge the head in to cut?

Adjusting the carriage locking (brake) mechanism 1. Remove the deflecting device as above 2. Loosen the setscrew for the backing screw (also on the left side of the carriage-shown just below the “Striebig” nameplate in the drawing) 3. Make adjustment to the backing screw #32 from behind with 6mm Allen wrench so that the screw…

See Full Answer

Why are the saw kerfs in my grid laths getting wider?

See Full Answer

Why are my cuts burning and chipping?

Parallel Guide (Healing/Tracking) Adjustment for Striebigs Models – Econom, Standard, Automat, Optisaw I, Optisaw I Plus, Optisaw II & Standard TRK 1. Test for healing by making a climb-scoring (or main-blade scoring) pass and returning back through with a finish cut. Retract the riving knife (splitting wedge) before cutting. The test is the same, but…

See Full Answer

How do I square my saw cuts?

Test cutting and squaring an Econom, Standard, Automat, Optisaw I, Optisaw I Plus, Optisaw II, Optisaw II, Optisaw Automatic & Standard TRK The intent of these instructions is to accomplish this efficiently and accurately, with minimal amount of material usage. It is important the frame is level and is not sagging or raised in the…

See Full Answer

How do I adjust the step out of my cut that occurs while backscoring?

Parallel Guide (Healing/Tracking) Adjustment for Striebigs Models – Econom, Standard, Automat, Optisaw I, Optisaw I Plus, Optisaw II & Standard TRK 1. Test for healing by making a climb-scoring (or main-blade scoring) pass and returning back through with a finish cut. Retract the riving knife (splitting wedge) before cutting. The test is the same, but…

See Full Answer

How do I change a motor belt?

Procedure for Removal and Installation of Motor Drive Belt for Striebigs Models – Econom, Standard, Automat, Optisaw I, Optisaw I Plus, Optisaw II & Standard TRK 1. Disconnect power to saw. 2. Rotate head to the horizontal cutting position. 3. Position and lock carriage to a comfortable working height. 4. Open belt cover (item #8).…

See Full Answer